ICP has a long-running legacy of innovation in the concrete accessories industry. Starting in 1966, George Hartzheim founded our first concrete company, manufacturing dobies for the rebar fabricators and placers. Since the inception of the company, the rebar fabricator and placer was our primary product for concrete reinforcement. Today we continue the legacy of innovation with new products and new markets. We service dealers and contractors nationwide with high quality concrete spacers, plastic spacers, rebar ties, slab bolsters, and more. If you’re looking for a supplier with a proven history and excelling in performance, look no further.
We boast the largest inventory of dobies in the country, ready to ship when your order is placed. If you’ve ever been told you have to wait for dobies, the word wait is not in our vocabulary. We test our mix designs daily to ensure that your orders meet the criteria you expect.
Our plastic parts are free of flash and produced from injection molds with the latest technology. Our regular strength dobies will average a compressive strength between 4,000 and 5,000 psi. We regularly stock higher strength dobies for DOT work in many sizes. Our range of bricks, dobies, and form spreaders is the largest inventoried product line in the industry. For our line of plastic bar supports we use engineered resins and our load strengths are among the best in the industry.
Inland Concrete Products
14760 Santa Ana Ave.
Fontana, Ca 92337
(909) 356-5399
Standard post published to Inland Concrete Products at June 23, 2021 15:20
How do you put rebar on a concrete slab?
Tie into the existing pieces When you’re signing up with 2 concrete pieces, link the two with rebar to keep them at the same height. Drill the holes as deep as you can (the entire length of the bit) so the rebar fits comfortably into the holes. Place pieces of rebar and connect them into the grid.
Inland Concrete is a rebar spacer manufacturer in West Fontana. ICP sells rebar spacer supplier. ICP ships slab bolster.
Standard post published to Inland Concrete Products at June 21, 2021 14:45
Reinforcement partly buried in the subbase does not offer fracture width control. Without supporting chairs or pre-cast concrete blocks, reinforcement usually ends up in the bottom of the slab or buried in the subbase.Reinforcement partly buried in the subbase does not offer fracture width control. Without supporting chairs or pre-cast concrete blocks, support generally winds up in the bottom of the piece or buried in the subbase.
Inland Concrete is a slab bolster wholesaler near Sierra Madre. Inland Concrete Products distributes concrete accessories manufacturer. Inland Concrete ships concrete rebar chairs.
Standard post published to Inland Concrete Products at June 18, 2021 15:10
US Sizes
US/Imperial bar sizes give the diameter in systems of 1⁄8 inch (3.2 mm) for bar sizes # 2 through # 8, so that # 8 = 8⁄8 inch = 1-inch (25 mm) diameter. The cross-sectional location, as offered by πr ², exercises to (bar size/9.027) ², which is approximated as (bar size/9) ² square inches. For instance, the area of # 8 bar is (8/9) ² = 0.79 square inches.
Inland Concrete Products is a concrete rebar chairs distributor in southern California. Inland Concrete Products manufactures slab bolster wholesaler. ICP designs plastic spacers.
Standard post published to Inland Concrete Products at June 16, 2021 15:20
Do I need rebar in footing?
Footings with large bearing locations or unsteady soil can gain from adding rebar to prevent splitting. When rebar is placed within a footing, it ought to be totally encased in concrete by a minimum of 3 inches on all sides. When rebar is allowed to forecast out of the footings, it is prone to more quick deterioration.
Inland Concrete Products is a concrete chairs for rebar manufacturer in southern California. Inland Concrete Products distributes plastic spacers distributor. Inland Concrete designs concrete accessories.
Standard post published to Inland Concrete Products at June 14, 2021 14:45
The ‘hook and pull’ technique of moving welded wire reinforcement into the defined area is an inadequate method specialists ought to avoid.The “hook and pull” approach of moving bonded wire reinforcement into the defined place is an ineffective technique contractors need to avoid.
ICP is a concrete chairs for rebar wholesaler near Skyforest. Inland Concrete Products supplies concrete dobies manufacturer. Inland Concrete offers concrete dobies.
Standard post published to Inland Concrete Products at June 11, 2021 15:10
Requirements for contortions on steel bar support were not standardized in U.S. building and construction until about 1950. Modern requirements for deformations were developed in “Tentative Specifications for the Deformations of Deformed Steel Bars for Concrete Reinforcement”, ASTM A305-47T. Consequently, modifications were made that increased rib height and reduced rib spacing for certain bar sizes, and the certification of “tentative” was gotten rid of when the upgraded standard ASTM A305-49 was provided in 1949. The requirements for deformations found in existing requirements for steel bar strengthening, such as ASTM A615 and ASTM A706, to name a few, are the same as those defined in ASTM A305-49.
ICP is a concrete chairs supplier in southern California. Inland Concrete Products sells concrete dobies wholesaler. Inland Concrete designs concrete dobies.
Standard post published to Inland Concrete Products at June 09, 2021 15:20
What’s the difference in between a concrete slab and a cement slab?
The difference in between cement and concrete Although the terms cement and concrete frequently are utilized interchangeably, cement is in fact a component of concrete. Concrete is generally a mixture of aggregates and paste. The aggregates are sand and gravel or crushed stone; the paste is water and portland cement.
Inland Concrete is a concrete accessories wholesaler near Wrightwood. Inland Concrete Products sells rebar dobies supplier. Inland Concrete offers slab bolster.
Standard post published to Inland Concrete Products at June 07, 2021 14:45
Vertical positioning tolerance for reinforcement in slabs-on-ground is ± ¾ inch from the specified location. For piece densities 12 inches or less, the concrete cover tolerance is - 3/8 inch measured perpendicular to the concrete surface and the reduction in cover can not exceed one-third of the specified cover. Oftentimes, the cover tolerance bypasses the vertical placement tolerance. Properly putting and supporting support will help make sure compliance with these vertical positioning tolerances.
Inland Concrete Products is a concrete dobies distributor close to Burbank. ICP manufactures dobies distributor. Inland Concrete Products manufactures dobies.
Standard post published to Inland Concrete Products at June 02, 2021 15:20
The type of and meant use of concrete effects the need for rebar reinforcement. Rebar needs to be positioned at the center of or somewhat above the center of the concrete piece– for this reason why it should be a certain thickness for best outcomes. “Chairs” is a term used to specify assistances positioned underneath rebar grids to prop them up.
ICP is a dobies manufacturer close to Bloomington. ICP makes concrete dobies wholesaler. Inland Concrete Products ships concrete chairs for rebar.